LDP 190 Diesel Filter Differential Pressure Test System

Automated liquid-filter test system for measuring diesel-filter differential pressure according to ISO 4020/6.3, with controlled flow, pressure and temperature plus automated venting.

Flow range
25–2000 L/h
Pressure
Up to 20 bar
Temperature
20–80 °C
Standard
ISO 4020/6.3
Diesel fuel filters ISO 4020/6.3 20–80 °C Automated venting
ISO 4020/6.3

Model Overview

Model System purpose Standards / method Core fit
LDP 190 Controlled liquid-loop system for differential-pressure testing and valve leak checks ISO 4020/6.3 Diesel-fuel filter characterisation, liquid-filter development and valve tightness testing

Key Features

ISO 4020 differential-pressure testing

Measures the pressure loss of diesel fuel filters at defined flow and temperature conditions.

Wide flow-rate range

Covers liquid flow rates from 25 to 2000 L/h for diverse filter sizes and operating points.

Controlled pressure and temperature

Adjusts system pressure and heats the test medium from 20 to 80 °C.

Automated specimen venting

A dedicated mode removes residual air after specimen changes without manual intervention.

Conditioning bypass

The liquid can be temperature-conditioned through a bypass while the specimen is replaced.

Multi-liquid capability

Supports diesel, diesel substitutes and application-specific liquids for other filter types.

Technical Specifications

Parameter Unit Value / Description
CONTROLLED PARAMETERS
Flow-rate range L/h 25–2000
System pressure before specimen bar Maximum 20
System pressure after specimen bar Maximum 5
Test-medium temperature °C 20–80
Maximum specimen envelope mm 500 × 500 × 500
SYSTEM DATA
Test medium Diesel and diesel substitutes
Compressed-air supply bar 7–9; dry and particle-free
Cooling-water temperature °C Maximum 13
User interface Touchscreen, keyboard and mouse
Communication USB and Ethernet
Dimensions (W × H × D) mm 2600 × 2050 × 1300
Weight kg Approx. 1000

Published values support initial model selection. Confirm final configuration, utilities, accessories and calibration scope during technical review.

Applications

Diesel-filter pressure drop

Differential-pressure testing of diesel fuel filters according to ISO 4020/6.3.

Other liquid filters

Characterisation of pressure loss using compatible alternative test liquids.

Valve leak testing

Tightness checks of valves under controlled liquid pressure.

Operating-condition simulation

Variation of flow, pressure and temperature to reproduce machinery operating conditions.

Automated acceptance tests

Repeatable software-guided testing for production and incoming inspection.

Filter design comparison

Benchmarking of media, pleat and housing designs using controlled liquid circulation.